Axonal model for temperature stimulation

Abstract Recent studies indicate that a rapid increase in local temperature plays an important role in nerve stimulation by laser. To analyze the temperature effect, our study modified the classical HH axonal model by incorporating a membrane capacitance-temperature relationship. The modified model successfully simulated the generation and propagation of action potentials induced by a rapid increase in local temperature when the Curie temperature of membrane capacitance is below 40 °C, while the classical model failed to simulate the axonal excitation by temperature stimulation. The new model predicts that a rapid increase in local temperature produces a rapid increase in membrane capacitance, which causes an inward membrane current across the membrane capacitor strong enough to depolarize the membrane and generate an action potential. If the Curie temperature of membrane capacitance is 31 °C, a temperature increase of 6.6–11.2 °C within 0.1–2.6 ms is required for axonal excitation and the required increase is smaller for a faster increase. The model also predicts that: (1) the temperature increase could be smaller if the global axon temperature is higher; (2) axons of small diameter require a smaller temperature increase than axons of large diameter. Our study indicates that the axonal membrane capacitance-temperature relationship plays a critical role in inducing the transient membrane depolarization by a rapidly increasing temperature, while th...
Source: Journal of Computational Neuroscience - Category: Neuroscience Source Type: research