The Impact of Target Vessel Anatomy and Bridging Stent Geometry on Branched Endovascular Aortic Repair Outcomes

CONCLUSION: Target vessel diameter, bridging length (gap), and horizontal misalignment seemed to be associated with adverse target vessel outcomes. This may be solved with more customised endograft solutions to reduce the negative impact of the latter parameter.PMID:38685310 | DOI:10.1016/j.ejvs.2024.04.028
Source: PubMed: Eur J Vasc Endovasc ... - Category: Surgery Authors: Source Type: research