The impact of skin preparation method on electrocardiogram quality in horses
CONCLUSION AND CLINICAL RELEVANCE: This study suggests that skin preparation by cleansing and/or shaving does not have a significant effect on equine ECG signal quality. When gel is used, textile electrodes are a practical alternative for Ag/AgCl electrodes, as they produce ECG recordings of the same quality.PMID:38434162 | PMC:PMC10880388
Source: The Canadian Veterinary Journal - Category: Veterinary Research Authors: Persephone McCrae Hannah Spong Amin Mahnam Yana Bashura Wendy Pearson Source Type: research
More News: Alcoholism | Canada Health | Chloride | Electrocardiogram | Skin | Study | Veterinary Research