A simple air-liquid interface exposure system for exposing cultured human 3D epidermis and cornea to PM2.5 collected through cyclonic separation

In this study, we developed an air-liquid interface exposure system for exposing cultured human 3D epidermis and cornea to PM2.5 collected through cyclonic separation. PM2.5 suspension was nebulized in an acrylic chamber, and the resulting mist was pumped through a diffusion dryer into a glass exposure chamber. A particle counter was connected to the exposure chamber to continuously measure the spatial mass concentration of PM. Human 3D epidermis was cultured in the exposure chamber. Exposure of the human 3D epidermis to PM aerosol increased interleukin-8 release into the media around 50 µg/m3. Mass concentrations above 100 µg/m3 caused cell death. Furthermore, a human corneal model showed similar responses against PM2.5 exposure as 3D epidermis. The air-liquid interface exposure system developed in this study is considered useful for evaluating the health effects induced by environmental PM2.5 and can be used as an alternative to experiments involving actual human or animals.PMID:38296530 | DOI:10.2131/jts.49.61
Source: Journal of Toxicological Sciences - Category: Toxicology Authors: Source Type: research