Sensitivity investigation of open-ended coaxial probe in skin cancer detection

In this study, we aim to provide a comprehensive examination of this method, including the minimum detectable tumor size by using a three-layer skin model via simulation and demonstrated that open-ended coaxial probe method can be used for detection of early-stage skin cancer. The smallest detecting size are subject to different subtypes: for BCC, inside the skin is 0.5  mm radius × 0.1 mm height; for SCC, inside the skin is 1.4 mm × 1.3 mm in radius and height; the smallest distinguishing size of BCC is 0.6 mm × 0.7 mm in radius and height; for SCC is 1.0 mm × 1.0 mm in radius and height; for MM is 0.7 mm × 0.4 mm in radius and h eight. The experiment results showed that sensitivity was affected by tumor dimension, probe size, skin height, and cancer subtype. The probe is more sensitive to cylinder tumor radius than height growing on the surface of the skin while the smallest size probe is the most sensitive among the workin g probes. We provide a detailed systematic evaluation of the parameters employed in the method for further applications.