Uterine slow wave: directionality and changes with imminent delivery

Objective. The slow wave (SW) of the electrohysterogram (EHG) may contain relevant information on the electrophysiological condition of the uterus throughout pregnancy and labor. Our aim was to assess differences in the SW as regards the imminence of labor and the directionality of uterine myoelectrical activity. Approach. The SW of the EHG was extracted from the signals of the Icelandic 16-electrode EHG database in the bandwidth [5, 30] mHz and its power, spectral content, complexity and synchronization between the horizontal (X) and vertical (Y) directions were characterized by the root mean square (RMS), dominant frequency (domF), sample entropy (SampEn) and maximum cross-correlation (CCmax) of the signals, respectively. Significant differences between parameters at time-to-delivery (TTD) ≤7 versus>7 days and between the horizontal versus vertical directions were assessed. Main results. The SW power significantly increased in both directions as labor approached (TTD  ≤ 7d versus>7d (mean ±SD):  = 0.12 ± 0.10 versus 0.08 ± 0.06 mV;  = 0.12 ± 0.09 versus 0.08 ± 0.05 mV), as well as the dominant frequency in the horizontal direction ( = 9.1 ± 1.3 versus 8.5 ± 1.2mHz) and the synchronization between both directions ( = 0.44 ± 0.16 versus 0.36 ± 0.14). Furth ermore, its complexity decreased in the vertical direction ( = 6.13·10−2 ± 8.7·10−3 versus 6.50·10−2 ± 8.3·10−3), suggesting a higher cell-to-cell electrical coupli...