Comparison of Two Minimally Invasive Osteosynthesis Techniques for Radial Head Fractures in Paediatric Patients

CONCLUSIONS The comparison of the two methods of minimally invasive osteosynthesis revealed no statistically significant difference, namely not even when both the methods were compared based on the degree of displacement. When Kirschner wire is used, the possibility to remove the metal implant in the outpatient setting is considered to be an advantage. The drawback consists in potential penetration of the sharp Kirschner wire in the radiocapitellar joint, which we did not encounter when the second technique of osteosynthesis was used. The advantage of Prévot nail includes a lower risk of pin-tract infection. Key words: minimally invasive osteosynthesis, radial head, fracture, child.PMID:35815489
Source: Acta Orthopaedica - Category: Orthopaedics Authors: Source Type: research