Antithrombotic use and bleeding risk in patients with atrial fibrillation: findings from a multipayer analysis.
CONCLUSION: Levels of thromboprophylaxis for high-risk AF patients in real-world data differ significantly from current medical guidelines for stroke prevention. PMID: 26690040 [PubMed - as supplied by publisher]
Source: Journal of Comparative Effectiveness Research - December 23, 2015 Category: Journals (General) Tags: J Comp Eff Res Source Type: research

Study: Boston Scientific’s Watchman cheaper than drugs in reducing afib stroke risk
A study comparing the stroke risk for atrial fibrillation patients treated with Boston Scientific‘s (NYSE:BSX) Watchman device with the anticoagulant drug warfarin and non-warfarin oral anticoagulants found Watchman to be more cost-effective than its counterparts. Watchman is a catheter-delivered cardiac implant designed to close off the left atrial appendage, to prevent blood clots from forming there that could later cause a stroke. The study, published online in the Journal of the American College of Cardiology, showed that the Watchman device was cost-effective at 7 years at a cost of $42,994 per quality-adjust...
Source: Mass Device - December 15, 2015 Category: Medical Equipment Authors: Brad Perriello Tags: Wall Street Beat Cardiovascular Cardiac Implants Clinical Trials Boston Scientific Reimbursement Source Type: news

Time to Cost-Effectiveness Following Stroke Reduction Strategies in AF Warfarin Versus NOACs Versus LAA Closure
ConclusionsBoth NOACs and LAAC with the Watchman device were cost-effective relative to warfarin, but LAAC was also found to be cost-effective and to offer better value relative to NOACs. The results of this analysis should be considered when formulating policy and practice guidelines for stroke prevention in AF.
Source: Journal of the American College of Cardiology - December 14, 2015 Category: Cardiology Source Type: research

MassDevice.com +3 | The top 3 medtech stories for November 24, 2015
Say hello to MassDevice +3, a bite-sized view of the top three medtech stories of the day. This feature of MassDevice.com’s coverage highlights our 3 biggest and most influential stories from the day’s news to make sure you’re up to date on the headlines that continue to shape the medical device industry.   3. Ocular Therapeutix launches another pivotal for Dextenza eye drug-device combo Ocular Therapeutix said today that it launched another pivotal trial for its Dextenza drug-device combination, its 2nd study of the treatment for an allergic conjunctivitis indication. Bedford, Mass.-based Ocular Th...
Source: Mass Device - November 24, 2015 Category: Medical Equipment Authors: MassDevice Tags: News Well Plus 3 Source Type: news

Report: Medicare proposal would broaden coverage for Boston Scientific’s Watchman
The Centers for Medicare & Medicaid Services are reportedly considering broadening the coverage for Boston Scientific‘s (NYSE:BSX) Watchman anti-stroke device, according to an unidentified official with the federal health insurer. Leerink Partners analyst Danielle Antalffy, citing a Bloomberg report, wrote today that the CMS official “clarified that CMS is proposing to pay for Watchman for a subset of the patients who currently would be eligible for the device under the FDA-approved label,” or patients at high risk for stroke and bleeding and/or contraindicated to long-term warfarin use. “Whi...
Source: Mass Device - November 24, 2015 Category: Medical Equipment Authors: Brad Perriello Tags: Cardiac Implants Cardiovascular Wall Street Beat Boston Scientific Centers for Medicare and Medicaid Services (CMS) Reimbursement Source Type: news

Boston Scientific dips on Medicare reimbursement hit for Watchman anti-stroke device
Boston Scientific (NYSE:BSX) shares took a hit yesterday after a Centers for Medicare & Medicaid Services proposal that would limit coverage for the Watchman anti-stroke device. Investors also likely reacted to a pair of Class II recalls from the FDA, sending BSX shares down -4.2% to $18.01 apiece yesterday. Watchman, a transcatheter implant designed to seal off the left atrial appendage to prevent the formation of blood clots that could cause stroke, was approved by the FDA in March and asked for a CMS coverage decision in May. The federal health insurer proposed to limit coverage for Watchman to patients in approv...
Source: Mass Device - November 12, 2015 Category: Medical Equipment Authors: Brad Perriello Tags: Cardiac Implants Cardiovascular Recalls Boston Scientific Cardiac Rhythm Management Stroke Source Type: news

Cost effectiveness of left atrial appendage closure versus Warfarin for stroke risk reduction in non-valvular Atrial Fibrillation in CMS patients
Stroke is the most severe and debilitating consequence of atrial fibrillation (AF), with many patients ranking the resultant disability as worse than death. Warfarin, the established first-line therapy, is effective at reducing ischemic stroke, but is associated with increased bleeding risk and lower quality of life (QoL). Left atrial appendage closure (LAAC) with the Watchman Device has been found to be superior to warfarin at reducing risk of stroke in AF patients. This analysis sought to assess the cost effectiveness of LAAC versus warfarin for stroke prevention in non-valvular AF from the perspective of the US Centers ...
Source: Value in Health - May 1, 2015 Category: Global & Universal Authors: V. Reddy, R. Akehurst, S.L. Amorosi, S. Armstrong, S. Beard, C. Knight, C. Taggart, D. Holmes Source Type: research

Abstract 304: Developing a Patient Registry for Atrial Fibrillation to Improve The Quality of Stroke Prevention in a Safety Net Institution Session Title: Poster Session III
Conclusions: A baseline assessment of stroke prophylaxis among atrial fibrillation patients in a safety net health system demonstrates nonguideline-concordant anticoagulation use among low-risk patients and suboptimal anticoagulation use among high-risk patients, patterns that could not be explained by HAS-BLED score.
Source: Circulation: Cardiovascular Quality and Outcomes - April 29, 2015 Category: Cardiology Authors: Oronce, C. I., Valdez, C., Anderson, S. L., Vlasimsky, T. B., Marrs, J. C., Richesin, S. D., Hanratty, R. Tags: Session Title: Poster Session III Source Type: research