Filtered By:
Condition: Hemorrhagic Stroke
Education: Study

This page shows you your search results in order of date. This is page number 10.

Order by Relevance | Date

Total 12507 results found since Jan 2013.

Utilizing fcn techniques for accurate cerebral stroke partitioning in brain ct
This study compares the segmentation accuracy and precision of various fully convolutional neural network (FCN) methods applied to cerebral stroke detection.
Source: Journal of Medical Imaging and Radiation Sciences - August 23, 2023 Category: Radiology Authors: Jing-Wen Chen, Koharu Kimura, Akari Matsushima, Takahide Okamoto, Nan-Hen Lu, Shih-Yen Hsu, Tai-Been Chen Source Type: research

Common Data Elements for Disorders of Consciousness: Recommendations from the Working Group on Hospital Course, Confounders, and Medications
This article outlines the process of the development of common data elements for hospital course, confounders, and medications to streamline definitions and variables to collect for clinical studies of DoC.
Source: Neurocritical Care - August 23, 2023 Category: Neurology Source Type: research

Amantadine for NeuroenhaNcement in acutE patients Study - a protocol for a prospective pilot proof of concept phase IIb study in intensive and intermediate care unit patients (ANNES)
Persisting coma is a common complication in (neuro)intensive care in neurological disease such as acute ischemic stroke, intracerebral hemorrhage or subarachnoid hemorrhage. Amantadine acts as a nicotinic rece...
Source: BMC Neurology - August 22, 2023 Category: Neurology Authors: Anna Hofmann, Corinna Blum, Constanze Single, Kamal Adeyemi, Patricia Schwarz, Vasileios Siokas, Tim W. Rattay, Helene A. H äberle, Reimer Riessen, Bettina Brendel, Iris Haug, Ruth Bösel, Manola Zago, Peter Martus, Ulf Ziemann, Annerose Mengel & hellip; Tags: Study Protocol Source Type: research

P064/122 Treatment of intracranial aneurysms with flow diversion in a real-world scenario - 10-year single center cohort
ConclusionOur series suggests that treatment with FD is feasible in a wide spectrum of cases, including aneurysms in different locations, sizes and morphology, ruptured and non-ruptured, reflecting a real-world scenario. Although available devices may differ, they seem to demonstrate comparable and adequate safety and effectiveness.Disclosure of InterestNothing to disclose
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Maia, C., Cruz, L., Alves, M., Pamplona, J., Carvalho, R., Baptista, M., Camara, C. P. D., Pinheiro, C., Papoila, A., Lopes Dos Reis, J. J., Fragata, I. Tags: 1.1 HAEMORRHAGIC - Aneurysms Source Type: research

P067/132 Cerebral vasospasm treatment using comaneci device - registry study
ConclusionThe Comaneci device has the potential to serve as a first-line device for providing therapeutic benefit to patients with SAH and vasospasm. However, future prospective trials are required.Disclosure of InterestNothing to disclose
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Hensler, J., Larsen, N., Christian, R., Nordmeyer, H., Breyer, T., Hesselmann, V., Jan, H., Jansen, O. Tags: 1.1 HAEMORRHAGIC - Aneurysms Source Type: research

P073/162 Clever: clinical evaluation of WEB 0.017 device in intracranial aneurysms. Final results for ruptured and enraptured aneurysms at 12 months
ConclusionThese results show good efficacy and safety results at 12 months, and no WEB related mortality, confirming safety and efficacy of WEB 0.017 use in unruptured and ruptured aneurysms.Disclosure of InterestIstvan Szikora has a consulting agreement with Microvention. I Szikora, Chr Cognard and L Spelle served as research coordinators for the CLEVER study
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Szikora, I., Cognard, C., Costalat, V., Wodarg, F., Herbreteau, D., Fischer, S., Möhlenbruch, M., Chrysanti, P., Klisch, J., Rautio, R., Jussi, N., Ansgar, B., Downer, J., Bester, M., Velasco, S., Liebig, T., Byrne, J., Pierot, L., Spelle, L. Tags: 1.1 HAEMORRHAGIC - Aneurysms Source Type: research

P077/180 Silk vista baby flow diverter stent for unruptured distal brain aneurysms: a Brazilian retrospective observational study
ConclusionThe SVB has high rates of technical success and an acceptable safety profile. Distal aneurysms may occlude slower due to relative oversizing of the devices and coils could help to improve the occlusion rate.Disclosure of InterestNothing to disclose
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Silva, J. M., Soares, G. M., Altikes, M., Junior, J. P., Coelho, A., Rezende, A. Tags: 1.1 HAEMORRHAGIC - Aneurysms Source Type: research

P082/226 Efficacy and safety of pipeline shield stents and flow-diverting stents without modified surfaces in patients with intracranial aneurysms
ConclusionThe treatment with Pipeline Shield stent was as safe as with FD stent without modified surfaces. However, they showed a greater occlusion efficacy during one-year evaluation period.Disclosure of Interestothing to disclose
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Garcia, J., Rodriguez, A., Vera, D. D., Lara, J. J., Sandoval, O., Ferreira, C., Serrano, S., Vargas, O., Garcia, D. M. Tags: 1.1 HAEMORRHAGIC - Aneurysms Source Type: research

P089/268 Safety and efficacy of the fourth-generation Acandis Acclino Flex Plus stent in managing complex intracranial aneurysms
ConclusionThe AFP stent demonstrated feasibility and favourable safety and efficacy in the treatment of complex aneurysms. These results support its clinical use and highlight the need for further studies to evaluate its performance in different aneurysm subsets and to determine its specific role in the endovascular treatment of aneurysms.Disclosure of InterestCK serves as consultants for Acandis GmbH (Pforzheim, Germany) and proctor for MicroVention Inc./Sequent Medical (Aliso Viejo, CA, USA). David Zopfs is on the speaker’s bureau of Philips (Amsterdam, the Netherlands) and lecturer for Amboss GmbH (Cologne, Germany).
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Goertz, L., Zopfs, D., Schönfeld, M., Schlamann, M., Kabbasch, C. Tags: 1.1 HAEMORRHAGIC - Aneurysms Source Type: research

P090/269 Comparative analysis between a second-generation (acandis acclino) and a first-generation (enterprise) stent system
ConclusionAdvanced stents offer reduced thromboembolic risk and comparable aneurysm occlusion to first-generation stents due to their flexible design and surface modification. These results support the clinical use of advanced stent systems, but further comparative studies are needed to conclusively evaluate the efficacy of stent-assisted coiling with the Acclino stent and other systems.Disclosure of InterestCK serves as consultants for Acandis GmbH (Pforzheim, Germany) and proctor for MicroVention Inc./Sequent Medical (Aliso Viejo, CA, USA). David Zopfs is on the speaker’s bureau of Philips (Amsterdam, the Netherlan...
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Goertz, L., Zopfs, D., Schönfeld, M., Turowski, B., Schlamann, M., Kabbasch, C. Tags: 1.1 HAEMORRHAGIC - Aneurysms Source Type: research

Cardiovascular and renal outcomes in patients with atrial fibrillation and stage 4 –5 chronic kidney disease receiving direct oral anticoagulants: a multicenter retrospective cohort study
AbstractThe role of direct oral anticoagulants (DOAC) in patients with atrial fibrillation (AF) and stage 4 –5 chronic kidney disease (CKD) is controversial. Electronic medical records from 2012 to 2021 were retrieved for patients with AF and stage 4–5 CKD receiving oral anticoagulants. Patients were separated into those receiving DOACs (dabigatran, rivaroxaban, apixaban, or edoxaban) or vitamin K ant agonists (VKA). Primary outcomes included ischemic stroke (IS), systemic thrombosis (SE), major bleeding, gastrointestinal bleeding, hemorrhagic stroke, acute myocardial infarction, cardiovascular death, and all-cause dea...
Source: Journal of Thrombosis and Thrombolysis - August 21, 2023 Category: Hematology Source Type: research

P124/272 Initial encounter with a cutting-edge mobile head CT scanner (Somatom On.site) in a neuro-intensive care unit
ConclusionThe study demonstrates the clinical effectiveness of modern mobile CT scanners in neurointensive care units. The Somatom On.site provides sufficient image quality, saves time and supports timely decision making. The integration of mobile CT scanners in NICUs improves patient care and workflow. Prospective studies are needed to validate these findings and assess the long-term impact in NICUs and other units, such as stroke units.Disclosure of InterestCK serves as consultants for Acandis GmbH (Pforzheim, Germany) and proctor for MicroVention Inc./Sequent Medical (Aliso Viejo, CA, USA).
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Goertz, L., Al-Sewaidi, Y., Habib, M., Ranft, A., Kabbasch, C. Tags: 3.1 OTHER - Innovation Source Type: research

P136/338 Intracranial vessel wall imaging - A tertiary centre initial experience
ConclusionOur centre’s experience recognises the role of MR-VWI in the imaging of ischaemic stroke, as well as its potential in management of acute unstable intracranial aneurysm. Clinical-radiological correlation remains imperative and emphasis is placed on understanding the potential technical pitfall of MR-VWI.Disclosure of InterestNothing to disclose for all authors
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Chung, R.-E., Kow, K., Qayyum, N., Joseph, J., Jadun, C. K., Nayak, S., Srivastava, S., Majeed, U., Hashim, Z., Tsang, K. Tags: 2.1 ISCHEMIC - Logistics Source Type: research

O13/126 Safety and efficacy of first-line double stent-retriever: the bifurcation elective thrombectomy with double y stentretriever (BETYS) prospective multicenter registry protocol
ConclusionThe BETYS registry is an ongoing prospective study regarding the use of double SR as first-line treatment in anterior circulation large vessel occlusions.Disclosure of InterestNothing to disclose.
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Perez-Garcia, C., Rosati, S., Lopez-Jurado, A. L.-F., Gomez-Escalonilla Escobar, C. I., Moreu, M. Tags: 2.3 ISCHEMIC - Treatment Source Type: research

O33/325 The efficacy and safety of Double Stentretrevier as a rescue method after failed thrombectomy
ConclusionRescue Mechanical thrombectomy using double-SR is associated with a higher rate of successful recanalization, first-pass effect, and relatively low rate of hemorrhagic complications. Further randomized control trials are needed to confirm results and long-term outcomes.Disclosure of InterestNothing to disclose.
Source: Journal of NeuroInterventional Surgery - August 21, 2023 Category: Neurosurgery Authors: Rikhtehgarghiasi, R., Deutschel, C., Yamac, E., Wallocha, M., Ayad, A., Li, Y., Chapot, R. Tags: 2.3 ISCHEMIC - Treatment Source Type: research