Age Effects of Bone Conduction Vibration Vestibular-evoked Myogenic Potentials (VEMPs) Using B81 and Impulse Hammer Stimuli

Conclusions: Age significantly affected c- and oVEMP amplitudes regardless of stimulus type (ACS, B81, IH). All stimuli are appropriate for eliciting c- and oVEMP in the young individuals. While ACS resulted in higher cVEMP corrected amplitudes, either ACS or B81 are appropriate for older individuals. However, for oVEMPs, higher response rates and larger amplitudes were noted for IH followed by B81 and ACS. Overall, the B81 performed well across the lifespan for c- and oVEMPs and may be a reasonable bone conduction vibration option for patients with absent ACS VEMPs, but at this time is not recommended as a replacement to ACS.
Source: Ear and Hearing - Category: Audiology Tags: Research Article Source Type: research
More News: Audiology | Study