Brady ‐arrhythmias in patients with atrial fibrillation and heart failure of reduced ejection fraction: is his‐bundle pacing superior to biventricular pacing༟

Conclusion: HBP was safe and more effective in improving the cardiac function and remodeling in patients with brady-arrhythmias, permanent AF and HFrEF compared with BVP.This article is protected by copyright. All rights reserved
Source: Pacing and Clinical Electrophysiology : PACE - Category: Cardiology Authors: Tags: ORIGINAL ‐ ELECTROPHYSIOLOGY Source Type: research