Outcomes of Open Complex Ventral Hernia Repairs With Retromuscular Placement of Poly-4-Hydroxybutyrate Bioabsorbable Mesh.

Conclusions. Complex hernia repairs using bioabsorbable mesh were conducted in a small cohort of high-risk patients. These data demonstrate good outcomes with limited morbidity and mortality. There were no recurrences. PMID: 31617453 [PubMed - as supplied by publisher]
Source: Surgical Innovation - Category: Surgery Authors: Tags: Surg Innov Source Type: research