Alteration of the intaglio surface of lithium disilicate glass-ceramic

ConclusionsExcessive etching, refiring, and adjustment by airborne-particle abrasion or diamond rotary instrument result in qualitative changes in surface condition. Adjustment by diamond rotary instrument results in appreciable surface damage.
Source: The Journal of Prosthetic Dentistry - Category: Dentistry Source Type: research