Determination of raltegravir and raltegravir glucuronide in human plasma and urine by LC-MS/MS with application in a maternal-fetal pharmacokinetic study

Publication date: Available online 27 August 2019Source: Journal of Pharmaceutical and Biomedical AnalysisAuthor(s): Fernanda de Lima Moreira, Maria Paula Marques, Geraldo Duarte, Vera Lucia LanchoteAbstractRaltegravir (RAL) is a HIV-integrase inhibitor recommended for treatment of HIV type 1 infection during pregnancy. The elimination of RAL to RAL glucuronide (RAL GLU) is mediated primarily by UDP glucuronosyltransferase 1A1 (UGT1A1). The present study shows the development and validation of 4 different methods for the analysis of RAL and RAL GLU in plasma and in urine samples. The methods were applied to evaluate the maternal-fetal pharmacokinetics of RAL and RAL GLU in a HIV-infected pregnant woman receiving RAL 400 mg twice daily. The sample preparation for RAL and RAL GLU analysis in 25 µL plasma and 100 µL diluted urine (10-fold with water containing 0.1% formic acid) were carried out by protein precipitation procedure. RAL and RAL GLU generate similar product mass fragments and require separation in the chromatographic system, so a suitable resolution was achieved for unchanged RAL and RAL GLU employing Ascentis Express C18 (75 x 4.6 mm, 2.7 µm) for both plasma and urine samples. The methods showed linearities at the ranges of 0.1-13.5 µg/mL RAL and 0.15-19.5 µg/mL RAL GLU in urine and 10-2000 ng/mL RAL and 2.5-800 RAL GLU in plasma. Precise and accurate evaluation showed coefficients of variation and relative errors ≤ 15%. The methods have ...
Source: Journal of Pharmaceutical and Biomedical Analysis - Category: Drugs & Pharmacology Source Type: research