Development and validation of a novel semi-homogenous clinical assay for quantitation of Ranibizumab in human serum.

In this report, we describe the development of a novel method that utilizes a high-affinity murine monoclonal anti-ranibizumab-VEGF-complexes antibody (MARA) reagent to measure ranibizumab in human serum. The assay format utilizes a semi-homogeneous solution phase step using a monoclonal antibody (the MARA) that binds specifically to the ranibizumab-VEGF complex, but not to either alone. This unique reagent exhibited low non-specific binding and high selectivity, increasing signal-to-noise readouts and maximizing assay sensitivity. The resulting MARA enzyme-linked immunosorbent assay (ELISA) has a lower limit of quantification of 15 pg/mL in human serum. In the assay, serum samples are incubated overnight with a mixture containing biotinylated-VEGF and MARA, which form a three-molecule complex with ranibizumab in the sample. These complexes are then captured onto streptavidin-coated wells, followed by enzymatic detection using a horseradish peroxidase-labeled-anti-murine antibody reagent and a colorimetric reaction. The assay conditions were optimized to allow for quantitative detection of "total" ranibizumab levels in serum. The assay was fully validated, establishing its high tolerance to sample matrix, as well as its suitable specificity, accuracy, dilution linearity, as well as intra- and inter-assay precision. The MARA ELISA's novel and unique approach has resulted in a considerably more sensitive ranibizumab PK assay compared to earlier versions of this assay. The MAR...
Source: Journal of Immunological Methods - Category: Allergy & Immunology Authors: Tags: J Immunol Methods Source Type: research