Failing to meet relative humidity targets for incubated neonates causes higher heat loss and metabolic costs in the first week of life

ConclusionRelative humidity from days 1‐8 was below the recommended target value for preterm infants and resulted in high evaporative and greater total body heat loss and additional metabolic cost. The findings pose numerous challenges, including nursing care and incubator design.This article is protected by copyright. All rights reserved.
Source: Acta Paediatrica - Category: Pediatrics Authors: Tags: Regular Article Source Type: research