Evaluation of the trend of set-up errors during the treatment period using set-up margin in prostate radiotherapy

This study aimed to develop an evaluation method of the temporal trends in a patient's specific prostate movement during treatment using image matching and margin values. This study included 65 patients who underwent prostate volumetric modulated arc therapy (mean treatment time, 87.2 s). Set-up errors were assessed using bone, inter-, and intra-fraction marker matching across 39 fractions. The set-up margin was determined by dividing the four periods into 39 fractions using Stroom's formula and correlation coefficient. The intra-fraction set-up error was biased in the anterior-superior (AS) direction during treatment. The temporal trend of set-up errors during radiotherapy slightly increased based on bone matching and inter-fraction marker matching, with a 1.6-mm difference in the set-up margin fractions 11 to 20. The correlation coefficient of the mean prostate movement during treatment significantly decreased in the superior-inferior direction, while remaining high in the left-right and anterior-posterior directions. Image matching contributed significantly to the improvement of set-up errors; however, careful attention is needed for prostate movement in the AS direction, particularly during short treatment times. Understanding the trend of set-up errors during the treatment period is essential in numerical information sharing on patient condition and evaluating the margins for tailored hypo-fractionated radiotherapy, considering the facility's image-guided radiation thera...
Source: Cancer Control - Category: Cancer & Oncology Authors: Source Type: research