Assessment of minimum target dose as a predictor of local failure after spine SBRT

CONCLUSIONS: Spine SBRT offers favorable local control; however, minimum dose to the GTV has a strong association with local control. Achieving GTV minimum dose of 14-15.3 Gy with single fraction SBRT is recommended whenever possible.PMID:38548114 | DOI:10.1016/j.radonc.2024.110260
Source: Radiotherapy and Oncology : journal of the European Society for Therapeutic Radiology and Oncology - Category: Radiology Authors: Source Type: research