Quantitative Assessment of the Heat Transfer Capacity of Ice Bags and their Cooling Effects on the Skin Surface and Core Temperature

This study quantifies heat energy transfer capacity of ice bags and evaluates their cooling effects on body temperature. Forty-eight healthy adults in their 20s were recruited. An ice bag wrapped in two layers of dry towel was applied to the forehead, neck, or palm of each participant for 10 min. The skin surface temperature, heat flow, and core temperature were recorded during the cooling and non-cooling periods, with energy transfer calculated by integrating heat flow over time. Over the non-cooling period, 31.4-53.6 kJ·m-2 of energy was dissipated over 10 min, whereas during the cooling period, the range increased to 180.0-218.7 kJ·m-2 over 10 min. Skin surface temperature decreased by 3.2-5.7°C, whereas core temperature was unchanged. Ice bag use augmented energy transfer by about 150-180 kJ·m-2 over 10 min, but this was insufficient for rapid whole body cooling due to the small skin-surface area in contact with the ice bag. The measured energy transfer indicated that topical ice bag application absorbs insufficient energy to affect core temperature. Quantitative assessment of energy transfer was shown to inform the safe and appropriate use of thermotherapy.PMID:38419315 | DOI:10.18926/AMO/66671
Source: Acta Medica Okayama - Category: General Medicine Authors: Source Type: research
More News: General Medicine | Pain | Skin | Study