Safety of skipping the tract dilation step for EUS-guided biliary drainage in patients with unresectable malignant biliary obstruction (with video)

ConclusionEmploying the tract dilation step during EUS-BD was a significant risk factor for early AEs. Metal stents with a delivery diameter  <  7.5 Fr can be inserted directly without the tract dilation step, resulting in lower early AE rates.
Source: Surgical Endoscopy - Category: Surgery Source Type: research