Design parameters comparison of bubble column, airlift and stirred tank photobioreactors for microalgae production

In this study, three different photobioreactor types (stirred tank, airlift, bubble column) were characterized and compared for microalgae production. Hydrodynamics, mass transfer, and power consumption were determined for various aeration rates (0.9, 1.2, 1.5 L/min), and stirring speeds (100, 200 rpm), and Chlorella sorokiniana growth performance was compared under the conditions that provided the highest volumetric mass transfer and the lowest mixing time. Photo-bioreactor homogenization was good as indicated by low mixing times (< 10 s). Bubble column had the highest volumetric mass transfer due to its sparger design. Gas holdup and volumetric mass transfer coefficient were found to increase with the air flow rate and stirring speed. For stirred tank, bubble column, and airlift photobioreactors, maximum specific growth rates of C. sorokiniana were 0.053, 0.061, 0.057 h-1, and biomass productivities were 0.064, 0.097, 0.072 gdw/L.day, respectively. Under the conditions tested, growth was limited by the volumetric mass transfer in the airlift and stirred tank and bubble column was the best option for producing microalgae. These findings pave way for more extensive use of these systems in producing microalgae and provide a basis to compare photobioreactors of different designs.PMID:38226988 | DOI:10.1007/s00449-023-02952-8
Source: Bioprocess and Biosystems Engineering - Category: Biomedical Engineering Authors: Source Type: research