Mean compression ratio of a self-expandable valve is associated with the need for pacemaker implantation after transcatheter aortic valve replacement

ConclusionsThe compression ratio of the SEV was positively associated with the risk of PPMI after TAVR, and the association was most significant in the annular and supravalvular planes. The compression ratio may also affect the time to PPMI.