QRS complex and T wave planarity for the efficacy prediction of automatic implantable defibrillators
Conclusions
The analysed data suggest that QRS and T wave non-planarity might offer distinction between patients who are at greater risk of death despite ICD protection and those who are likely to use the defibrillator protection.
Source: Heart - Category: Cardiology Authors: Hnatkova, K., Andrsova, I., Novotny, T., Vanderberk, B., Sprenkeler, D., Junttila, J., Reichlin, T., Schlögl, S., Vos, M. A., Friede, T., Bauer, A., Huikuri, H. V., Willems, R., Schmidt, G., Sticherling, C., Zabel, M., Malik, M. Tags: Open access Cardiac risk factors and prevention Source Type: research