Predictors of long-term intraocular pressure control after lens extraction in primary angle closure glaucoma: results from the EAGLE trial

Conclusion Patients with primary angle closure glaucoma/PAC are 10 times more likely to maintain drop-free good IOP control with initial CLE surgery than LPI. Non-Chinese ethnicity, higher baseline IOP and using glaucoma drops prior to randomisation are predictors of worse long-term IOP response.
Source: British Journal of Ophthalmology - Category: Opthalmology Authors: Tags: Editor's choice Original articles - Clinical science Source Type: research