Chem Pharm Bull (Tokyo). 2023;71(3):213-219. doi: 10.1248/cpb.c22-00685.ABSTRACTThe purpose of the present study was to provide the experimental and theoretical basis of bioequivalence (BE) dissolution test criteria for formulation development of high solubility-low permeability drugs. According to the biowaiver scheme based on the biopharmaceutics classification system (BCS), for BCS class III drugs, a test formulation and a reference formulation are predicted to be BE when 85% of the drug dissolves within 15 min (T85% < 15 min) in the compendial dissolution test. However, previous theoretical simulation studies have suggested that this criterion may possibly be relaxed for use in practical formulation development. In the present study, the dissolution profiles of 14 famotidine formulations for which BE has been clinically confirmed were evaluated by the compendial dissolution test at pH 1.2 and 6.8. The plasma concentration-time profiles of famotidine formulations were simulated using the dissolution data. In addition, virtual simulations were performed to estimate the range of dissolution rates to be bioequivalent. The fastest and slowest dissolution rates among the famotidine formulations were T85% = 10 min and T85% = 60 min at pH 6.8, respectively. The virtual simulation BE study suggested that famotidine formulations can be bioequivalent when T85% < 99 min. In the case of BCS III drugs, the rate-limiting step of oral drug absorption is the membrane permeation proc...