The P300 Auditory Evoked Potential in Cochlear Implant Users: A Scoping Review

Conclusion This review has contributed with evidence that shows the importance of applying a controlled P300 protocol to diagnose and monitor CI users. Regardless of the stimuli used to elicit P300, we noticed a pattern in the increase in latency and decrease in amplitude in CI users. The user's experience with the CI speech processor over time and the speech test results seem to be related to the P300 latency and amplitude measurements. [...] Thieme Revinter Publicações Ltda. Rua do Matoso 170, Rio de Janeiro, RJ, CEP 20270-135, BrazilArticle in Thieme eJournals: Table of contents  |  Abstract  |  open access Full text
Source: International Archives of Otorhinolaryngology - Category: ENT & OMF Authors: Tags: Systematic Reviews Source Type: research