Filtered By:
Source: The Annals of Thoracic Surgery
Condition: Thrombosis

This page shows you your search results in order of relevance.

Order by Relevance | Date

Total 20 results found since Jan 2013.

Long-Term Risk of Ischemic Stroke After the Cox-Maze III Procedure for Atrial Fibrillation
Conclusions This multicenter study showed a low incidence of perioperative and long-term postoperative ischemic stroke/TIA after CM-III. Although general risk of ischemic stroke/TIA was reduced, patients with CHA2DS2-VASc score 2 or greater had a higher risk compared with score 0 or 1. Complete left atrial appendage excision may be an important reason for the low ischemic stroke rate.
Source: The Annals of Thoracic Surgery - July 20, 2017 Category: Cardiovascular & Thoracic Surgery Source Type: research

Clinical Significance of Spontaneous Echo Contrast on Extracorporeal Membrane Oxygenation
Conclusions SEC on VA-ECMO resulted in an increased risk of intracardiac thrombus and stroke. Maintaining pulsatility while the patient is on ECMO may result in a decreased chance of developing SEC and stroke.
Source: The Annals of Thoracic Surgery - February 16, 2017 Category: Cardiovascular & Thoracic Surgery Source Type: research

Valve-Sparing Root Replacement vs Composite Valve Grafting in Aortic Root Dilation: A Meta-Analysis
ConclusionsAortic valve sparing appears to be safe, and associated with reduced late mortality, thromboembolism/stroke and bleeding compared with composite valve grafting. Late durability is equivalent. Aortic valve sparing should be considered in patients with favorable aortic valve morphology.Graphical abstract
Source: The Annals of Thoracic Surgery - January 23, 2020 Category: Cardiovascular & Thoracic Surgery Source Type: research

Risk of Intraatrial Thrombi After Thoracoscopic Ablation in Absence of Heparin and Appendage Closure
Conclusions Thoracoscopic ablation of AF can be associated with a risk of left atrial appendage thrombus formation and possibly also stroke. With administration of heparin during the ablation, followed by occlusion of the left atrial appendage as a part of the procedure, this risk can be effectively reduced.
Source: The Annals of Thoracic Surgery - August 25, 2017 Category: Cardiovascular & Thoracic Surgery Source Type: research

The Subclavian Intraaortic Balloon Pump: A Compelling Bridge Device for Advanced Heart Failure
Conclusions The SC-IABP provided excellent hemodynamic support with minimal morbidity and mortality, allowed for extensive rehabilitation, and permitted more than 90% of patients to receive their intended therapy. Therefore, SC-IABP is a compelling bridge device for patients with advanced congestive heart failure.
Source: The Annals of Thoracic Surgery - July 28, 2015 Category: Cardiovascular & Thoracic Surgery Source Type: research

Factors Associated with Prolonged Survival in Left Ventricular Assist Device Recipients
ConclusionsPreoperative diabetes and amiodarone use were associated with poor long-term survival in LVAD recipients. Development of early complications of stroke, gastrointestinal bleeding, hemolysis, or pump thrombosis was also associated with poor long-term survival. Early diagnosis and treatment of these complications may improve survival in LVAD recipients.
Source: The Annals of Thoracic Surgery - October 12, 2018 Category: Cardiovascular & Thoracic Surgery Source Type: research

Reversal and Resumption of Antithrombotic Therapy in LVAD- Associated Intracranial Hemorrhage
ConclusionsReversal of anticoagulation appears safe following LVAD-associated intracranial hemorrhage, though inadequate reversal was common. Resumption of warfarin±antiplatelet was associated with fewer fatal and non-fatal thrombotic events compared to antiplatelets alone, though more non-fatal hemorrhage events occurred.
Source: The Annals of Thoracic Surgery - February 12, 2019 Category: Cardiovascular & Thoracic Surgery Source Type: research

Continuous-Flow Left Ventricular Assist Device Survival Improves with Multidisciplinary Approach
ConclusionsImplementing a comprehensive multidisciplinary approach substantially improved outcomes for CF-LVAD recipients.
Source: The Annals of Thoracic Surgery - March 8, 2019 Category: Cardiovascular & Thoracic Surgery Source Type: research

Reversal and Resumption of Antithrombotic Therapy in LVAD-Associated Intracranial Hemorrhage
ConclusionsReversal of anticoagulation appears safe after LVAD-associated intracranial hemorrhage, though inadequate reversal was common. Resumption of warfarin ± antiplatelet was associated with fewer fatal and nonfatal thrombotic events compared with antiplatelets alone, though more nonfatal hemorrhage events occurred.
Source: The Annals of Thoracic Surgery - June 20, 2019 Category: Cardiovascular & Thoracic Surgery Source Type: research

Novel Formula to calculate 3-D Angle between Inflow Cannula and Device Body of HeartMate II LVAD
ConclusionsWe established a novel formula to mathematically calculate actual 3D angles between inflow cannula and device body of HeartMate II. The formula would help investigators to validate their findings of the relationship between 2D projected angle (from CXR) and device thrombosis.
Source: The Annals of Thoracic Surgery - June 27, 2019 Category: Cardiovascular & Thoracic Surgery Source Type: research

Novel Formula to Calculate Three-Dimensional Angle Between Inflow Cannula and Device Body of HeartMate II LVAD
ConclusionsWe established a novel formula to mathematically calculate actual 3D angles between inflow cannula and device body of HeartMate II. The formula would help investigators to validate their findings of the relationship between 2D projected angle (from CXR) and device thrombosis.
Source: The Annals of Thoracic Surgery - December 14, 2019 Category: Cardiovascular & Thoracic Surgery Source Type: research

Long-Term Outcomes of the Maze Procedure Combined With Mitral Valve Repair: Risk of Thromboembolism Without Anticoagulation Therapy
Conclusions Adopting appropriate selection criteria for discontinuing anticoagulation therapy, the majority of patients receiving concomitant mitral repair and the Maze procedure can discontinue warfarin with excellent long-term safety profiles.
Source: The Annals of Thoracic Surgery - June 23, 2015 Category: Cardiovascular & Thoracic Surgery Source Type: research

Aortic Remodeling After Endovascular Repair of Complicated Acute Type B Aortic  Dissection
Conclusions TEVAR for complicated aTBAD results in low 30-day and 1-year mortality rates, with higher reintervention rates than observed with open operations. TEVAR is effective in thrombosing and stabilizing the size of the thoracic FL. The abdominal aortic FL remains patent and must be carefully scrutinized for long-term aneurysm formation.
Source: The Annals of Thoracic Surgery - December 17, 2016 Category: Cardiovascular & Thoracic Surgery Source Type: research

Predictors of Atrial Fibrillation After Coronary Artery Bypass Grafting: A  Bayesian Analysis
Conclusions This prospective Bayesian analysis identified five independent preoperative predictors of POAF after isolated CABG with cardiopulmonary bypass: CHA2DS2-VASc score, severe obesity, preoperative β-blocker use, preoperative antiplatelet therapy, and renal failure. The main interest in the CHA2DS2-VASc score as a predictor of POAF is that it is a simple and widely used bedside tool. Patients with these independent predictors of POAF may constitute a target population to test preventive strategies, such as non-antiarrhythmic and antiarrhythmic drugs.
Source: The Annals of Thoracic Surgery - December 18, 2016 Category: Cardiovascular & Thoracic Surgery Source Type: research

Evolution of Simplified Frozen Elephant Trunk Repair for Acute DeBakey Type I Dissection: Midterm Outcomes
Conclusions Simplified FET for treating acute DeBakey type I dissection has evolved and remained safe. It promotes aortic remodeling, and simplifies management of chronic aortic complications.
Source: The Annals of Thoracic Surgery - December 6, 2017 Category: Cardiovascular & Thoracic Surgery Source Type: research