Filtered By:
Specialty: Transplant Surgery
Condition: Bleeding
Procedure: Heart Valve Surgery

This page shows you your search results in order of date.

Order by Relevance | Date

Total 4 results found since Jan 2013.

Can the intermittent low-speed function of left ventricular assist device prevent aortic insufficiency?
In this study, the Jarvik 2000 device, which is programmed to reduce the pump speed each minute for 8  s, was chosen to examine this potential effect. Prospectively collected data of 85 heart transplant-eligible Jarvik 2000 recipients who met the study criteria (no pre-existing AI and aortic valve surgery) were retrospectively analyzed for the incidence, correlating factors, and clinical outcomes o f de novo AI. All data were provided by the Japanese Registry for Mechanically Assisted Circulatory Support. De novo AI occurred in 58 patients, 23 of whom developed at least moderate AI during a median support duration of 23.5...
Source: Journal of Artificial Organs - January 9, 2021 Category: Transplant Surgery Source Type: research

Type II Minimal ‐Invasive Extracorporeal Circuit for Aortic Valve Replacement: A Randomized Controlled Trial
Abstract Extracorporeal circulation triggers systemic inflammatory response and coagulation disorders which may lead to unfavorable clinical outcome. A type II minimally‐invasive extracorporeal circuit (MiECC) is a closed system with markedly reduced artificial surface as compared to conventional extracorporeal circuits (CECC). The aim of this study was to investigate and compare inflammatory responses, complement activation and selected clinical end‐points in isolated surgical aortic valve replacement (SAVR) performed with a type II MiECC circuit or a CECC. Fifty patients were prospectively randomized to MiECC or CECC...
Source: Artificial Organs - February 12, 2018 Category: Transplant Surgery Authors: Erich Gygax, Hans ‐Ulrich Kaeser, Mario Stalder, Brigitta Gahl, Robert Rieben, Thierry Carrel, Gabor Erdoes Tags: Main Text Source Type: research

Mid-term results of 17-mm St. Jude Medical Regent prosthetic valves in elder patients with small aortic annuli: comparison with 19-mm bioprosthetic valves
This study was designed to compare the mid-term outcomes after aortic valve replacement (AVR) between 17-mm mechanical heart valves (MV) and 19-mm bioprosthetic valves (BV) in elderly patients with small aortic annuli. Between 2000 and 2011, 127 consecutive patients (mean age 79 years; 87 % female) underwent AVR for aortic valve stenosis with a small aortic annulus. 19-mm BV (n = 67) was implanted. When the 19-mm BV did not fit the annulus, 17-mm St. Jude Medical Regent prosthetic mechanical valve (n = 60) was used instead of an aortic root-enlargement procedure. The follow-up rate was 94.0 % in the BV group, and 98...
Source: Journal of Artificial Organs - September 1, 2014 Category: Transplant Surgery Source Type: research

Efficacy of Prophylactic Intra‐Aortic Balloon Pump Therapy in Chronic Heart Failure Patients Undergoing Cardiac Surgery
This study investigated the efficacy of prophylactic intraoperative intra‐aortic balloon pump (IABP) usage in chronic heart failure patients with severely reduced left ventricular function undergoing elective cardiac surgery. Between January 2008 and December 2012, 107 patients with severely reduced left ventricular ejection fraction (LVEF <35%) received prophylactic intraoperative IABP implantation during open‐heart surgery. Surgical procedures performed were isolated coronary artery bypass grafting (CABG) in 35 patients (32.7%), aortic valve replacement in 12 (11.2%), mitral valve repair or replacement in 15 (14.0...
Source: Artificial Organs - February 1, 2014 Category: Transplant Surgery Authors: Yalin Yildirim, Simon Pecha, Mathias Kubik, Yousuf Alassar, Tobias Deuse, Samer Hakmi, Hermann Reichenspurner Tags: Thoughts and Progress Source Type: research