Evaluation of accuracy and characteristics of tooth-color matching by intraoral scanners based on Munsell color system: an in vivo study

AbstractTo compare the accuracy of visual and instrumental methods for tooth-color matching based on three attributes in the Munsell color system and to investigate the characteristics of intraoral scanners for tooth-color matching. Shades of the cervical, middle, and incisal third region of 130 maxillary anterior teeth were matched visually by an experienced prosthodontist (EP) using Vita classical A1-D4 (VC) and Vita System  3D-Master (V3D) shade guides, and digitally by a spectrophotometer (Vita Easyshade V, VE) and two intraoral scanners (3Shape TRIOS 3, T3; TRIOS 4, T4). VE was used as a reference. The reproducibility of the three test groups was examined by repeating the measurements in triplicate. The overall tru eness of the three test groups (from high to low) was T3 >  EP >  T4 for VC values (p <  0.01), and T3, EP >  T4 (p <  0.01) for V3D. The trueness of T3 in incisal regions was lower than cervical and middle regions. When hue or lightness was correct, the mismatched chroma in test groups was smaller than VE (p <  0.01). The repeatability of EP was the poorest (p <  0.01). The color-matching trueness of T3 was higher than EP and T4. The reproducibility of intraoral scanners was better than visual methodology.
Source: Odontology - Category: Dentistry Source Type: research
More News: Dentistry | PET Scan | Study