Hemoadsorption with CytoSorb ® and the early course of linezolid plasma concentration during septic shock

We present the case of a 61-year-old female patient with known Ulrich Turner syndrome who treated supportively with CytoSorb® and with linezolid due to a Staphylococcus epidermidis bloodstream infection as part of her intensive care treatment for septic shock. After establishment of a new adsorber, 600  mg of linezolid administered over 1 h. Linezolid levels measured before adsorber inlet (cpre) and after adsorber outlet (cpost) at 0, 15, 60, 120 and 480  min after starting infusion. Out of the ten samples, only the cpre samples 60 min (3.25 mg/l) and 120 min (4.7 mg/l) showed sufficiently high linezolid levels (therapeutic range 3–9 mg/l). After 480 min, cpre decreased to 2.8 mg/l, cpost increased to 1.85 mg/l, and thus clearance decreas ed to 67.86 ml/min (from 200 ml/min at 60 min), with greatly reduced adsorption capacity of CytoSorb® after 8  h. A loading dose (additional 600 mg) would have been urgently needed. Linezolid therapy under hemadsorption with CytoSorb® requires a clear indication and close monitoring of levels to avoid underdosing.
Source: Journal of Artificial Organs - Category: Transplant Surgery Source Type: research