High-Fidelity Patient Simulation Incorporated Into a Flipped Classroom Improves Students' Long-Term Knowledge Retention of Acute Organophosphorus Pesticide Poisoning

In this study, we aimed to explore the incorporation of HFPS into the FC and the impact on the long-term (3 months after classes) knowledge retention of medical undergraduate students learning about acute organophosphorus pesticide poisoning (AOPP). Methods Eighty-two fifth-year medical students were randomly divided into an HFPS group (HG, n = 40) and an FC group (FG, n = 42). A postclass quiz and preinternship quiz were performed to assess the short-term knowledge acquisition and long-term (3 months after classes) knowledge retention of both groups of students. Feedback questionnaires were administered immediately after the class and before the internship to assess the students' self-perceived competency. Results In the postclass quiz, the scores achieved by the students from the HG and FG were 15.58 ± 2.69 and 14.62 ± 2.19, respectively. No significant difference was found between the 2 groups (P = 0.19). In the preinternship quiz, the scores achieved by the students from the HG (14.50 ± 2.16) were significantly higher than those achieved by the students from the FG (11.40 ± 2.07, P
Source: Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare - Category: Medical Devices Tags: Empirical Investigations Source Type: research