Evaluation of the Lubricating Effect of Hyaluronic Acid on Contact Lenses Using a Pendulum-Type Friction Tester Under Mimicking Physiological Conditions

Objective: To evaluate the lubricating effect of hyaluronic acid (HA) on soft contact lenses (SCLs) measured using a pendulum-type friction tester. Methods: We measured the coefficient of friction (CoF) of narafilcon A, delefilcon A, and etafilcon A with polyvinylpyrrolidone (PVP), daily disposable SCL material, using a modified pendulum-type friction tester. Sample SCLs were set on an acrylic plastic half-ball and placed into the polyethylene terephthalate hemisphere cup filled with 0.4 mL of test lubricants that included saline and 0.05%, 0.1%, 0.2%, 0.3%, 0.4%, and 0.5% (wt/vol) HA (molecular weight, 850 kDa). The viscosities of saline and HA were measured using an Ubbelohde viscometer. Results: The CoF of the SCL under a low concentration (0.05%) of HA was the lowest and significantly lower than saline in narafilcon A and delefilcon A (P
Source: Eye and Contact Lens: Science and Clinical Practice - Category: Opthalmology Tags: Article Source Type: research
More News: Opthalmology | Science