Getting on target: Development of the novel, prozone-resistant, dual antibody rapid test (DART) for the LABScreen single antigen bead (SAB) assay.

In conclusion, the DART protocol accurately detects HLA antibodies independent of the prozone effect. Implementation of DART is an easy way to overcome the prozone effect without compromising HLA antibody detection. PMID: 31040048 [PubMed - as supplied by publisher]
Source: Human Immunology - Category: Allergy & Immunology Authors: Tags: Hum Immunol Source Type: research