Co-P decorated nanoporous copper framework for high performance flexible non-enzymatic glucose sensors

Publication date: Available online 16 April 2019Source: Journal of Electroanalytical ChemistryAuthor(s): Huang Chen, Peng Sun, Meijia Qiu, Min Jiang, Jie Zhao, Dongxue Han, Li Niu, Guofeng CuiAbstractIn response to the challenges posed by diabetes, portable glucose sensors with enzyme-free catalytic materials have received great attention in recent years. Herein, a facile strategy for fabricating inexpensive and efficient electrochemical sensors is proposed. Flexible copper clad laminate (FCCL) can be firstly decorated with nanoporous copper (NP Cu) through electrodepositing Cu-Sn alloy and dealloying the Sn element. Then Co-P is further electrodeposited onto the NP Cu/FCCL and the final Co-P/NP Cu/FCCL composite electrode exhibits high catalytic activity for glucose. The great performance of the Co-P/NP Cu/FCCL mainly derives from the enlarged surface area of the NP Cu and the high electrocatalytic activity of Co-P. This electrode exhibits a high sensitivity of 1818 μA cm−2 mM−1, low limit of detection of 378 nM (S/N = 3), fast response time of 4 s, a wide linear dynamic range of 0.5 μM to 10.0 mM, good anti-interference performance, excellent repeatability and considerable stability for glucose detection. The well-designed structure for catalyzing glucose in high efficiency enable the Co-P/NP Cu/FCCL a potential candidate for future flexible electrochemical sensors.Graphic abstractA hierarchical three-dimensional Co-P decorated nanoporous copper on a...
Source: Journal of Electroanalytical Chemistry - Category: Chemistry Source Type: research