Differentiation of mild keratoconus from corneal warpage according to topographic inferior steepening based on corneal tomography data

We report two cases of suspicious asymmetric bow tie and inferior steepening on topographic evaluations with reflection (Placido) and projection (Scheimpflug). Rotating Scheimpflug corneal and anterior segment tomography (Oculus Pentacam HR, Wetzlar, Germany) ® was performed in the first case, with a maximal keratometric value (Kmax) of 43.2 D and an overall deviation value from the Belin/Ambrósio Enhanced Ectasia Display (BAD-D) of 1.76, which was observed in the study eye (OD). BAD-D was 6.59 in the fellow eye, which had clinical findings that were c onsistent with keratoconus stage 2. The second case presented with a Kmax of 45.3 D and BAD-D of 0.76 in OD and 1.01 in OS. This patient had discontinued wearing soft contact lens less than 1 day prior to examination. Corneal tomographic data enabled us to distinguish mild or forme fruste keratoconu s from contact lens-induced corneal warpage, and similar findings were observed on curvature maps.RESUMO O presente estudo tem por objetivo relatar dois casos suspeitos que apresentam bow tie assim étrico e encurvamento inferior nas avaliações topográficas de reflexão (Placido) e projeção (Scheimpflug). A tomografia de córnea e segmento anterior com o sistema Scheimpflug (Oculus Pentacam HR, Wetzlar, Alemanha)® mostrou no primeiro caso, a ceratometria máxima (Kmax) de 43,2 D e o valo r D no Belin/Ambrósio Enhanced Ectasia Display (BAD-D) de 1,76 no olho estudado (OD). O olho contralateral apresentava BAD-D de 6,59 e ach...