A case report of a distal radius fracture treated with a dorsal spanning plate augmented with fragment specific fixation

We present a 43-year-old man who fell 5 ft onto his outstretched right hand. On examination, there was gross swelling and tenderness of the right wrist with no neurovascular deficit. Radiographs confirmed a comminuted intra-articular displaced distal radius fracture. He was treated with a dorsal spanning plate fixation combined with radiostyloid and volar buttress plates. Follow-up at 2 months showcased intact hardware with good fracture healing. The dorsal spanning plate was removed 4 months after the procedure with radiographs demonstrating adequate alignment and healing without failure. The patient reported no complaints and minimal functional disability. We highlight a case of augmenting a dorsal spanning plate with fragment-specific plate fixation for a comminuted intra-articular displaced distal radius fracture.PMID:38666097 | PMC:PMC11045250 | DOI:10.1093/jscr/rjae260
Source: Hand Surgery - Category: Surgery Authors: Source Type: research