Comparison of solid-phase red cell adherence and microcolumn agglutination technology using untreated and enzyme-treated red blood cells

This study was undertaken to detect and identify alloantibodies by performing antibody screen (ABS) and antibody identification (ABID) testing using SPRCA and CAT, with and without ficin-treated RBCs. Residual patient samples collected between 1 December 2020 and 19 May 2021 were saved, de-identified, and frozen at ≤-30°C before testing for alloantibodies. Seventy antibodies were detected in 53 samples among the 203 samples that underwent an ABS. Of those samples, 150 (73.0%) were nonreactive, 47 (23.1%) yielded positive results with both CAT and SPRCA, and six (3.0%) yielded positive ABS results with SPRCA only. Fifty-three samples that underwent ABID by both methods yielded eight samples with antibodies identified by SPRCA only. Additional enhancement of the CAT method by the use of ficin-treated RBCs was required to detect seven of the eight SPRCA-only antibodies; one sample remained nonreactive regardless. SPRCA testing detected clinically significant antibodies without the addition of enzyme-treated RBCs that was necessary in the CAT testing.PMID:38179782 | DOI:10.2478/immunohematology-2023-024
Source: Immunohematology - Category: Hematology Authors: Source Type: research
More News: Hematology | Study