Comparison of estimations of urinary bladder volume in different scanning positions using 2D linear dimension formula and 3D bladder circumference tracing in client-owned cats

Can J Vet Res. 2024 Apr;88(2):55-65.ABSTRACTUrinary bladder volume (UBV) can be estimated using point-of-care ultrasound. The purpose of this study was to compare 2 UBV estimation methods, i.e., three-dimensional (3D) bladder circumference tracing and 2-dimensional (2D) linear bladder dimension formula, against actual bladder volumes in awake client-owned cats and identify the best scanning position for UBV estimations. Up to 3 paired sets of orthogonal longitudinal and transverse bladder ultrasound images were acquired by a trained clinician from 21 cats positioned in dorsal, right lateral, and left lateral recumbency. UBV estimation was performed with these images by 2 different observers using both methods. Actual bladder volumes were measured through urethral catheterization and compared to the estimated UBV using Lin's concordance correlation coefficient and Bland-Altman analyses. Considering all positions, both methods showed substantial strength-of-agreement with actual bladder volumes; the 3D bladder circumference method (ρc = 0.963, 95% CI: 0.952 to 0.974) with a significant median bias of -4.08 mL (P < 0.001, IQR -7.63 to -0.68 mL, LOA -48.55 to 21.75 mL) and the 2D linear dimension method (ρc = 0.974, 95% CI: 0.966 to 0.982) with a median bias of -0.82 mL (P = 0.686, IQR -3.89 to 4.05 mL, LOA -35.23 to 35.21 mL). Scanning in left lateral recumbency provided the strongest strengths-of-agreement and precision against actual bladder volumes for both methods. Rega...
Source: Canadian Journal of Veterinary Research - Category: Veterinary Research Authors: Source Type: research