Filtered By:
Specialty: Transplant Surgery
Source: The International Journal of Artificial Organs

This page shows you your search results in order of date.

Order by Relevance | Date

Total 60 results found since Jan 2013.

In-hospital stroke and mortality trends after left ventricular assist device implantation in the United States from 2017 to 2019
CONCLUSIONS: Our study found a significant downtrend in the in-hospital mortality rates among patients with LVAD without substantial changes in stroke rate trends over the study timeframe. As stroke rates remained steady, we hypothesize that improved management along with better control of blood pressure, could have played an important role in survival benefit over the study time frame.PMID:37387231 | DOI:10.1177/03913988231183723
Source: The International Journal of Artificial Organs - June 30, 2023 Category: Transplant Surgery Authors: Jose Lopez Justin Mark Waseem Wahood Nader Lamaa Mauricio Danckers Source Type: research

Should we touch tricuspid valve at the time of LVAD implantation? A young patient series
CONCLUSION: Although the risk of late RVF may increase in patients with preoperative severe TI, not intervening in TI during LVAD implantation does not cause adverse clinical outcomes in the early period.PMID:37334781 | DOI:10.1177/03913988231181604
Source: The International Journal of Artificial Organs - June 19, 2023 Category: Transplant Surgery Authors: Soner Yavas Umit Kervan Mehmet Karahan Sinan Sabit Kocabeyoglu Dogan Emre Sert Ozgur Ersoy Burcu Demirkan Ahmet Temizhan Mehmet Ali Ozatik Source Type: research

Concomitant intra-aortic balloon pump and veno-arterial extracorporeal membrane oxygenation for postcardiotomy cardiogenic shock
Int J Artif Organs. 2023 Apr 26:3913988231170890. doi: 10.1177/03913988231170890. Online ahead of print.ABSTRACTWe aimed to compare the outcomes of ECMO with and without IABP for postcardiotomy cardiogenic shock. The study included 103 patients who needed ECMO for postcardiotomy cardiogenic shock. Patients were grouped according to the use of IABP into ECMO without IABP (n = 43) and ECMO with IABP (n = 60). The study endpoints were hospital complications, successful weaning, and survival. Patients with IABP had lower preoperative ejection fraction (p = 0.002). There was no difference in stroke (p = 0.97), limb ischemic (p ...
Source: The International Journal of Artificial Organs - May 1, 2023 Category: Transplant Surgery Authors: Amr A Arafat Abdulmalik A Almedimigh Khaled D Algarni Huda H Ismail Claudio Pragliola Adam I Adam Mohammed AlBarrak Ahmed Osman Monirah A Albabtain Tarek M Tantawy Source Type: research

Outflow cannula alignment in continuous flow left ventricular devices is associated with stroke
Int J Artif Organs. 2023 Mar 9:3913988231154284. doi: 10.1177/03913988231154284. Online ahead of print.ABSTRACTWe sought to evaluate whether differences in left ventricular assist device (LVAD) canula alignment are associated with stroke. There is a paucity of clinical data on contribution of LVAD canulae alignment to strokes. We conducted a retrospective analysis of patients who underwent LVAD implantation at Houston Methodist hospital from 2011 to 2016 and included those who had undergone cardiac computed tomography (CT) with contrast. LVAD graft alignment using X-ray, echocardiography, and cardiac CT was evaluated. The ...
Source: The International Journal of Artificial Organs - March 10, 2023 Category: Transplant Surgery Authors: Mahwash Kassi Tanushree Agrawal Jiaqiong Xu Hernan Gerardo Marcos-Abdala Raquel Araujo-Gutierrez Thomas Macgillivray Erik E Suarez Rayan Yousefzai Nadia Fida Ju H Kim Imad Hussain Ashrith Guha Barry Trachtenberg Arvind Bhimaraj Su Min Chang Jerry Estep Source Type: research