Calculation of attenuation parameter for Ir-192 gamma source in shielding materials

Conclusion: In conclusion, a 10 cm thickness of clay and clay-polyethylene mixture is sufficient to attenuate 87% and 89% of photons from Ir-192 source. The calculated linear attenuation coefficients for the three shielding materials are also consistently higher, about 7.5%, than that of the XCOM value for 380 keV photon.
Source: Journal of Medical Physics - Category: Physics Authors: Source Type: research
More News: Physics