Spinal Cord Medial Safe Zone for C2 Pedicle Instrumentation: An MRI Measurement Analysis

Study Design. Retrospective observational study. Objective. The aim of this study was to investigate the spinal cord safety margins for C2 instrumentation. Summary of Background Data. Intraoperative spinal cord injury during C2 spine surgery is a rare, but potentially life-threatening complication. Preoperative planning for C2 instrumentation mainly focuses on C2 pedicle bony dimensions on CT and the vertebral artery location and few studies have evaluated C2 spinal cord safety margins. Methods. We measured two distances in C2 bilaterally: C2 pedicle to dura distance (P-D), defined as a transverse line that measured the shortest distance between the medial wall of the C2 pedicle and the dural sac, and C2 pedicle to spinal cord (P-SC), defined as a transverse line that measured the shortest distance between the medial wall of the C2 pedicle and spinal cord. We defined the distances>4 mm as safe for instrumentation. Result. A total of 146 patients (mean age 71.2, 50.7% female) were included. The average distances were 5.5 mm for C2 left PD, 5.9 mm for C2 right P-D, 10.1 mm for C2 left P-SC, and 10.6 mm for C2 right P-SC. Twenty-eight (21.4%) patients had C2 P-D distances
Source: Spine - Category: Orthopaedics Tags: CERVICAL SPINE Source Type: research