Preoperative Computed Tomography Angiography for ALT Flaps Optimizes Design and Reduces Operative Time
Conclusion CTA is a useful tool for optimizing donor site selection for ALT flaps and reducing operative time. We believe that standard use of preoperative CTA in ALTs warrants further consideration. [...] Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USAArticle in Thieme eJournals: Table of contents | Abstract | Full text
Source: Journal of Reconstructive Microsurgery - Category: Surgery Authors: Schneider, Christopher M. Palines, Patrick A. Womac, Daniel J. Tuggle, Charles T. St Hilaire, Hugo Stalder, Mark W. Tags: Original Article Source Type: research