Adverse Events Detection Through Global Trigger Tool Methodology: Results From a 5-Year Study in an Italian Hospital and Opportunities to Improve Interrater Reliability

We present the main findings of the implementation of the Italian version of the GTT and evaluate efforts to improve the interrater reliability over time. Methods The Italian version of the GTT was developed and implemented at the San Bonifacio Hospital, a 270-bed secondary care acute hospital in Verona, Italy. Ten clinical records randomly selected every 2 weeks were reviewed from 2009 to 2014. Two-stage interrater reliability assessment between team members was conducted on 2 subsamples of 50 clinical records before and after the implementation of specific review rules and staff training. Results Among 1320 medical records reviewed, a total of 366 AEs were found with at least 1 AE on 20.2% of all discharges, 27.7 AEs/100 admissions, and 30.6 AEs/1000 patient-days. Adverse events with harm score E and F were respectively 58.2% (n = 213) and 38.8% (n = 142). First round interrater reliability was comparable with other international studies. The interrater agreement improved significantly after intervention (κ interrater I = 0.52, κ interrater II = 0.80, P
Source: Journal of Patient Safety - Category: Health Management Tags: The Health Care Manager Source Type: research