Low-dose computed tomography for axial spondyloarthritis: update on use and limitations

This article reviews what a ldCT is and its use and limitations for imaging axial spondyloarthritis. Recent findings Detection of structural damage in bone with CT is far superior to radiography and ldCT of the sacroiliac joints (SIJ) can now be done at radiation exposure levels equivalent to, or even less than, conventional radiography. ldCT should be considered a ‘first-choice’ test for arthritis imaging, and wherever available, SIJ ldCT may completely replace conventional radiography. Radiation exposure in the spine with ldCT is lower than conventional CT. However, it is unclear whether the additional information regarding structural damage changes in the spine provided by ldCT will alter patient management sufficiently often to merit switching from spinal radiography to ldCT in routine clinical practice. In addition, ldCT cannot assess osteitis disease activity for which MRI remains the best test. Summary ldCT of the sacroiliac joints (SIJ) can be done at radiation exposure levels equivalent to, or less than, radiography and ldCT may completely replace SIJ radiography. However, the role of spinal ldCT for spondyloarthritis is not clear and MRI is far superior for detecting disease activity.
Source: Current Opinion in Rheumatology - Category: Rheumatology Tags: SPONDYLOARTHROPATHIES INCLUDING PSORIATIC ARTHRITIS: Edited by Joerg Ermann Source Type: research