Endoscopic ‘suction room’ to treat complex enteral stump leaks after upper gastrointestinal surgery

We describe a new endoscopic approach to treat complex entero-cutaneous fistulas (CECF) by creating a “suction room” through placement of multiple stents (enteral, biliary and/or pancreatic) and a large nose-enteral suction tube inside the enteral stent maintained on a continuous negative aspiration suction.Between January 2016 and December 2019, six consecutive patients referred to our unit with CECF of the enteral stump after failed redo surgeries underwent creation of a “suction room.” In five patients, enteral, biliary and pancreatic stents were positioned before a nose-to-stent or nose-to-collection large 18 Fr tube placement. In one patient, a pancreatic stent was not placed. Technical and clinical success were achieved in all patients. Mean and median times of aspiration were 49 and 27 days, respectively, with a mean hospital stay of 56 days after the endoscopic procedure. Stents were successfully removed. Mean post-procedural follow-up was 17.3 months.Endoscopic creation of the “suction room” offers the unique possibility of treating complex entero-cutaneous fistulas in surgically altered sites, which are difficult to manage with standard endoscopic methods. [...] Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, GermanyArticle in Thieme eJournals: Table of contents  |  Abstract  |  open access Full text
Source: Endoscopy International Open - Category: Gastroenterology Authors: Tags: Innovation forum Source Type: research