Evaluating the severity of aortic coarctation in infants using anatomic features measured on CTA

ConclusionsCoA severity can be evaluated by using LDA with anatomical features. When quantifying the severity of CoA and risk of re-coarctation, both anatomical alternations at the CoA site and the growth of the patients need to be considered.Key Points• CTA is routinely ordered for infants with coarctation of the aorta; however, whether anatomical variations observed with CTA could be used to assess the severity of CoA remains unknown.• Using the diameter and area of the coarctation site adjusted to body growth as features, the LDA model achieved an accuracy of 88.6% and 90.2% in differentiating between the mild and severe CoA patients in the non-PDA group and PDA group, respectively.• The narrowest aortic diameter (CoA diameter) indexed to weight has a hazard ratio of 10.29 for re-coarctation.