Comparison of Clinical and Radiological Parameters with Two Different Surgical Methods for Anterior Cruciate Ligament Reconstruction

This study compared the clinical and radiological findings of nonanatomic transtibial (TT) technique with intraspongious fixation and anatomical anteromedial portal (AMP) technique with extracortical button implant in anterior cruciate ligament (ACL) reconstruction. A total of 54 patients with isolated ACL rupture were included in this prospective study. The patients who had the intraspongious fixation by nonanatomical TT technique were allocated to Group 1 (n = 27). The patients with extracortical fixation by anatomical AMP technique were placed in Group 2 (n = 27). The clinical scores of the patients were evaluated with the International Knee Documentation Committee Evaluation Form, Tegner activity score, and Lysholm II Functional Scoring. The tibial and femoral tunnels were evaluated with three-dimensional computed tomography. The kinematic examinations were performed with a Biodex System 3 Pro isokinetic dynamometer. There was no significant difference between the groups in terms of demographic data (p > 0.05). The postoperative clinical scores improved significantly in both the groups compared with the preoperative levels (p = 0.001), but there was no significant difference in the postoperative clinical scores between the groups (p > 0.05). In the extension and flexion of 60 to 180 degrees/s, the peak torque and the peak torque/body weight values of the repaired knee to intact knee ratios showed significant differences in favor of Group 2 (pâ€...
Source: Journal of Knee Surgery - Category: Orthopaedics Authors: Tags: Original Article Source Type: research