Measurement of ambulatory venous pressure and column interruption duration in normal volunteers

ConclusionsAMVP measured through the DFV does not reflect calf pump generated pressure events in GSV. A duplex method of measuring CID in GSV and posterior tibial vein is described. Duplex-derived CID is not significantly different from pressure-derived CID in the GSV.
Source: Journal of Vascular Surgery: Venous and Lymphatic Disorders - Category: Surgery Source Type: research