Dosimetric evaluation of automatic and manual plans for early nasopharyngeal carcinoma to radiotherapy

To investigate dosimetric differences and plan qualities between manual plans and automatic plans for nasopharyngeal carcinoma (NPC) in early stage, and provide better options to maximize the benefits. Sixteen cases diagnosed with early NPC were retrospectively investigated. Conventional step and shoot IMRT with 7-fields and full arc volumetric-modulated arc therapy (VMAT) with double arcs were manually generated by experienced planners and automatically generated by Auto-Planning module in Pinnacle3 respectively, such as IMRT manual-planning (mIMRT), IMRT auto-planning (aIMRT), VMAT manual-planning (mVMAT), and VMAT auto-planning (aVMAT) for each patient.
Source: Medical Dosimetry - Category: Radiology Authors: Source Type: research