Initial 3-year results of first human use of an in-body tissue-engineered autologous "Biotube" vascular graft for hemodialysis.

This study presents the initial 3-year results of the first in-human study of internal shunt restoration using completely autologous vascular grafts, "Biotubes," based on in-body tissue architecture. Biotubes (diameter, 6 mm; length, 7 cm) were prepared as autologous collagenous tubular tissues with approximately 0.5 mm wall thickness by embedding molds (two per patient), assembled with a silicone rod and a stainless steel pipe with many slits, into the patients' abdominal subcutaneous tissue for 2 months. Two female patients with end-stage renal disease were undergoing hemodialysis with a high probability of failure due to repeated stenosis every few months at the venous outflow regions over 1.5 years. Biotubes formed in both patients and were bypassed over the venous stenosis region of the arteriovenous shunt. After bypass with Biotubes without living cells, palpable thrill and typical turbulent flow pattern were observed by pulsed-wave Doppler. Follow-up angiography showed no signs of dilation or stenosis after implantation, and puncture could be performed easily without graft damage. In both cases, stenosis of Biotubes occurred after 3-4 months. In the first case, percutaneous transluminal angioplasty was not required for over 2 years after implantation even after the development of Biotube stenosis. In the second case, stenosis at the proximal anastomotic site of the Biotube became prominent, and percutaneous transluminal angioplasty was needed 7 months a...
Source: The Journal of Vascular Access - Category: Surgery Tags: J Vasc Access Source Type: research